Outdoor Unit Won't Start Capacitor vs Contactor

Complete diagnostic guide for AC outdoor units that won't start. Learn to identify capacitor vs contactor failures, electrical troubleshooting, and North Texas heat considerations.

Jupitair HVAC Team
11 min read

Outdoor Unit Won’t Start

When your AC outdoor unit fails to start on a hot North Texas day, the problem often lies with two critical electrical components: the capacitor or the contactor. Understanding how to distinguish between these failures can save you time and money while ensuring you get cooling restored quickly. This comprehensive guide will help you safely diagnose the issue and know when professional help is required.

Key Diagnostic Points:

  • Capacitor failures often cause humming sounds without fan or compressor operation
  • Contactor problems typically result in complete electrical silence
  • Both components are stressed by North Texas heat and electrical storms
  • Visual inspection can often identify the failed component
  • Professional replacement ensures safety and proper operation
  • Preventive maintenance significantly reduces failure rates

Understanding Your Outdoor Unit Components

The AC Capacitor: Energy Storage for Motor Startup

The capacitor stores and releases electrical energy to start your AC’s motors. Think of it as a temporary battery that provides the extra power boost needed to overcome motor inertia during startup.

Types of Capacitors:

  • Start capacitor: Provides initial motor starting torque
  • Run capacitor: Maintains motor efficiency during operation
  • Dual capacitor: Combines start and run functions for both fan and compressor
  • Most North Texas units use dual capacitors for space efficiency

How Capacitors Fail:

  • Internal breakdown from heat and electrical stress
  • Moisture infiltration causing short circuits
  • Aging electrolyte leading to reduced capacity
  • Physical damage from electrical surges

The Contactor: Electrical Switch for High-Voltage Control

The contactor is essentially a heavy-duty electrical switch that controls power to your outdoor unit’s major components. When your thermostat calls for cooling, it sends a low-voltage signal that activates the contactor.

Contactor Components:

  • Electromagnetic coil: Creates magnetic field when energized
  • Contact points: Metal contacts that close to complete electrical circuit
  • Springs: Return contacts to open position when power is removed
  • Housing: Protects internal components from weather and debris

Common Contactor Problems:

  • Burned or pitted contact points
  • Stuck contacts that won’t open or close
  • Failed electromagnetic coil
  • Mechanical wear from repeated cycling

ELECTRICAL SAFETY WARNING

Working with electrical components can be dangerous. Turn off power at the breaker before inspection. If you’re uncomfortable with electrical work, call our certified technicians immediately.

Distinguishing Capacitor vs. Contactor Failures

Capacitor Failure Symptoms

Characteristic Sounds:

  • Humming or buzzing from outdoor unit
  • Sound occurs when AC is turned on
  • Humming continues without fan or compressor starting
  • Most reliable indicator of capacitor failure

Operational Symptoms:

  • Fan motor attempts to start but fails
  • Compressor tries to start but can’t overcome inertia
  • Circuit breaker may trip from motor overload
  • Unit draws excessive electrical current

Visual Indicators:

  • Bulged or swollen capacitor case
  • Leaked electrolyte around capacitor
  • Burned or corroded terminals
  • Physical damage visible on capacitor

Contactor Failure Symptoms

Sound Characteristics:

  • Complete silence when AC should be running
  • No humming, clicking, or motor sounds
  • Thermostat calls for cooling but unit doesn’t respond
  • Absence of sound is key diagnostic clue

Electrical Symptoms:

  • No power reaching outdoor unit components
  • 24-volt control signal present but no response
  • Indoor unit may run but outdoor unit completely inactive
  • Total electrical disconnect between control and load

Visual Inspection Findings:

  • Burned or pitted contact points
  • Contacts stuck in open or closed position
  • Discolored or melted contactor housing
  • Physical damage to electrical connections

Safe Diagnostic Steps for Homeowners

Initial Safety Preparation

Power Safety:

  1. Turn off AC at thermostat
  2. Locate and turn off outdoor unit disconnect switch
  3. Turn off circuit breaker at electrical panel
  4. Use voltage tester to verify power is off
  5. Never skip electrical safety verification

Basic Visual Inspection:

  • Remove debris from around unit
  • Check for obvious damage to electrical components
  • Look for burned or melted wires
  • Note any unusual odors
  • Do not remove electrical panels without professional help

Simple Diagnostic Tests

Listen for Sounds:

  • Turn thermostat to cooling mode
  • Go outside and listen to outdoor unit
  • Humming = likely capacitor problem
  • Silence = likely contactor problem
  • Normal startup sounds = look elsewhere for problem

Check Circuit Breaker:

  • Look for tripped breaker position
  • Reset once if tripped
  • If it trips again immediately, call professional
  • Multiple trips indicate serious electrical problems

When to Call Professionals Immediately

Electrical Safety Hazards

Immediate Service Required:

  • Burning smells or visible smoke
  • Sparking or electrical arcing
  • Repeated circuit breaker trips
  • Turn off power and call immediately

High Priority Situations:

  • Complete system failure during extreme heat
  • Indoor temperatures above 85°F with vulnerable occupants
  • Any electrical safety concerns
  • Same-day emergency service available

Professional Diagnosis and Repair

Advanced Testing Procedures

Capacitor Testing:

  • Electrical testing with specialized meters
  • Capacitance measurement and comparison to ratings
  • Visual inspection for physical damage
  • Replacement with properly rated components

Contactor Testing:

  • Control voltage verification
  • Contact point inspection and testing
  • Mechanical operation assessment
  • Professional replacement ensures proper operation

Repair Costs and Timeline

Capacitor Replacement:

  • Component cost: $25-75
  • Labor: $150-250
  • Total repair: $175-325
  • Usually same-day service

Contactor Replacement:

  • Component cost: $50-150
  • Labor: $200-300
  • Total repair: $250-450
  • Emergency service add $100-200

North Texas Specific Considerations

Heat and Weather Impact

Extreme Temperature Stress:

  • Summer temperatures regularly exceed 100°F
  • Electrical components stressed by sustained heat
  • Frequent cycling increases wear
  • Capacitors particularly vulnerable to heat damage

Electrical Storm Damage:

  • Frequent thunderstorms create electrical surges
  • Power grid fluctuations affect equipment
  • Surge protection recommended
  • Both components vulnerable to electrical damage

Prevention Strategies

Annual Maintenance:

  • Professional tune-ups before peak season
  • Electrical connection inspection and tightening
  • Component testing and replacement as needed
  • Preventive maintenance much less expensive than emergency repairs

Environmental Protection:

  • Adequate clearance around outdoor unit
  • Protection from debris and weather
  • Surge protection for electrical components
  • Investment in protection pays for itself

FAQ: Outdoor Unit Startup Problems

Q: Why does my outdoor unit hum but not start? A: Humming without startup typically indicates capacitor failure. The motor is trying to start but can’t overcome inertia without the capacitor’s electrical boost. This requires immediate professional replacement to prevent motor damage.

Q: What causes these components to fail in North Texas? A: Heat, electrical storms, and frequent cycling cause most failures. North Texas’s extreme summer temperatures and thunderstorms create particularly harsh conditions for electrical components.

Q: Can I replace these components myself? A: While possible, electrical work can be dangerous and requires proper tools and knowledge. Professional replacement ensures safety, proper operation, and warranty coverage.

Q: How long do capacitors and contactors last? A: In North Texas climate, capacitors typically last 7-10 years while contactors last 10-15 years. High usage, extreme heat, and electrical issues can significantly reduce component life.

Q: Should I replace both if one fails? A: Not necessarily, but if both are old, replacing both during one service call saves labor costs and prevents a second failure soon after. Your technician can advise based on age and condition.

Q: What maintenance prevents these failures? A: Annual professional tune-ups, keeping the unit clean, ensuring proper electrical connections, and surge protection significantly reduce failure rates. Prevention is much less expensive than emergency repairs.

Q: Why does my breaker keep tripping? A: Repeated breaker trips usually indicate a failed capacitor causing motor overload, a bad compressor, or electrical problems. Never keep resetting a tripping breaker - call for professional diagnosis immediately.

Q: Can these problems damage other components? A: Yes, failed capacitors can damage motors if the system continues to operate. Failed contactors can cause electrical problems. Prompt professional repair prevents additional damage and costs.


Need Professional HVAC Service?

Our certified technicians are ready to help with repairs, maintenance, and installations.

24/7 Emergency Service • Licensed & Insured • Satisfaction Guaranteed

Last Updated: August 18, 2025

Jupitair HVAC serves all of North Texas including Plano, Frisco, McKinney, Allen, and surrounding areas. TACLA License #123456.

Jupitair HVAC Team

Jupitair HVAC Team

Licensed HVAC Professionals

Our team consists of licensed HVAC technicians and comfort specialists with over 15 years of experience serving North Texas. We're committed to providing honest, expert advice to help homeowners make informed decisions about their heating and cooling systems.

Credentials & Experience

Licensed HVAC Contractors NATE Certified Technicians 15+ Years Experience Locally Owned & Operated
Licensed & Insured
4.9/5 Customer Rating
24/7 Emergency Service

Related Topics

#AC not starting #capacitor failure #contactor problems #electrical troubleshooting #outdoor unit repair #North Texas AC #HVAC diagnosis #summer cooling

Need Professional HVAC Service?

Our certified technicians are ready to help with repairs, maintenance, and installations.